hayward blue essence troubleshooting

Hi Davy, I have a Hayward super flo matrix pump. Running very smoothly and pumping very hard. This is why we usually recommend a larger cell than the cell rating would suggest. ) and you should be able to feel debris lodged in the impeller with your fingertips. I put a new power cord socket in the water proof box, which feeds power to the pump, I shined up the power cord plug pins), (power cord is about 2.5 ft of 12 Ga, not wet, not laying on the ground) For Pools up to 40,000 gallons. I have great circulation, but I the problem is after the pump runs for around a half hour on the filter setting it barely has any force coming out of the jet. Filter. Hi Davy, I have a Hayward Super II which has been running well for years. Just replaced the upper lid on my Vari-flow and spider gasket, also changed out 300 lbs filter sand. Point the capacitor away from you and others, while discharging. Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. If thats not the problem, then it could be that you replaced the motor with a full rated motor, but the impeller (and old motor) was an uprated motor, or vice-versa. You can also turn off the pump at the breaker which provides power to the timer. My pool pump just doesnt turn on. Hi Kevin, I think I would check the capacitor(s), maybe replace them if they test weak, or look cracked or damaged. The print and bearings were replaced. Some advice? Hi Rob, If the pump is the same exact model and horsepower, it sounds like either; 1). If you have a power meter you can turn clock on and see if power is getting to the motor 110-120V. It could also be due to the air intake, or the filter pressure, Water around the base, check the motor bolts or seal plate clamp for tightness on the seal plate o-ring, and check drain plugs for tightness, but most likely its coming from around the outlet pipe, and dripping down to the base, or from the shaft seal, which leaks directly mid bottom, where motor connects. Good morning. look for a hi-voltage/low-voltage diagram on the motor label. "url": "https://blog.intheswim.com/"
AquaRite not displaying t-xx and getting inspect cell and check salt, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. How do I seal it? It ran all night and still going. my hayward filter assembly on top leaks at the seam between the top (held on by six bolts) and the bottom. Hi Shelly, sounds like maybe the board got wet, or there is a loose connection, or power supply issues. If it is on low it works properly. Maybe a complete reboot at the circuit breaker could be the answer, or a reset on the pump control panel. Any suggestions welcome. I changed the sand and it is still occurring. Most heaters can operate on 120V/240V, either one. On Jandy valves, the spurt may be from the lid, or from the center of the lid around the stem, from a broken or missing grease cap (grey valves), or from a crack/damage. Pump lid not on tight enough I have a brand new Hayward super pump for my inground pool that my husband bought last year..this morning i turned it on and when i checked it about an hour later i noticed it was off and water around the switch and the plug and i also noticed there must have been a leak in the hose where the water can be drained from the pool so im guessi g the hose sprung a leak and wet everything..i checked the timer and the breaker and switched them off and on again and still no power..i saw a switch on the back of the pump and flipped it off then on again and still no power..im guessing it couldve got fried but im hoping im wrong..please help. Tighten in a Pattern (tighten up the bolts in a N, S, E, W, or 12, 6, 9, 3 pattern). Make sure that the fitting that goes into the pump has no air leaks, which is the most common air leak area. "keywords": "",
The arrow should point in the same direction as the water flow. Old broken wires inside of the conduit could be the problem. 1. I have it set on a timer and when the pump comes on the flow rate is good but as the day goes on it becomes less and less. All the hoses have new Teflon tape and they are secured. Once I get it going, it works fine for as long as I leave it on. Higher horsepower motors are usually only 230V, above 2 hp, but lower hp motors are sometimes reversible, or have the ability to wire either with 110V or 220V, but they will say this on the motor label if they are (reversible) and have a diagram also. It worked great last year, and when i went to program it this year, it didnt work unless I switch it on and off manually. We opened our pool today, and when we went out to turn off the Hayward pump, after it ran for 7 hours, the plug was so hot it burned my fingers when unplugging it. Replace with the exact same MFD number, printed on the capacitor. Roger, I call that surging, when the pump catches prime, loses prime, catches again it can be a stuck skimmer weir or a pool noodle blocking water flow into the skimmer. Ive waited a few hours and tried again but no luck. There was alot of debris once I removed the assemblies and some water below wiring. Motor again started humming and had to repeat the above steps each time I moved to backwash. This time around I purchased the t-3 cell model since my pool is below 15k gallons. Check the capacitor, for bulging, cracking, or melting. I reached into the impeller and grabbed it but it seemed still tight. The most common areas for an air leak are the pump lid (is it as tight as possible? Just a thought Do you have it set at super chlorinate ? Breaker for the pump is not tripped. Wouldnt, the other three still be sufficient to filter? Sun was beating on it. It happens every time. I checked the voltage at the back of the motor and have 240 volts. LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the ' '' ''' - -- --- ---- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. ' However, I havent tried to spin the shaft. Hi Ric, is the SF service factor rating the same on both motors (new and old)? Perflex filters are particularly known (to me anyway) for building up oily deposits on the fingers or flex tubes, and clogging up quickly. 220v. When the centrifugal switch is pushed flat by the spinning shaft (or with your finger [power off! We purchased a Hayward D.E Filter last summer. Do you know what would cause this? how to watch past broadcasts on twitch. 1. Third, could be a clog in the main drain or skimmer (suction) pipes. Your salt level is between 2500-2600 parts per million (ppm). How To Fix The Problem If thats not it pull the motor out of the pump, and test the motor briefly to see if the sound continues, if so I would expect bad bearings, or perhaps a loose shim washer, inside the motor, under the front or rear end bell. "headline": "Hayward Pool Pump Troubleshooting",
2. Be sure the wiring is tight on both ends. Tried again and again to start, but just keep hearing a click sound and nothing happens. Thanks. pull the water through. Or buy a new motor. When impellers are clogged sometimes they surge. You could also adjust the pressure switch (on most heaters), to allow it to come on with slightly less pressure, (1 psi instead of 2 psi). Hello there, if he customer wants to install a VS pump (required in 2021 for all new pumps), they could do that now. If you need a new one in a few days, I would not consider getting one from Hayward, that could take a month. I was able to isolate all the other electrical circuits at the Aqua Logic power panel. Davy, Does the capacitor look bulged, cracked or leaking? Whats the best and safest way to troubleshoot? Do you have any ideas?? If power is reaching the motor, but nothing (no noise), look for any disconnected or severed wires in the back (shut off power first), if nothing, the motor may be dead. Look closely at the centrifugal switch on the rear of the shaft, to be sure its tight and is not missing parts (like the springs), engage the switch by hand (power off), to be sure that the stationary switch (located at 6 oclock) is disengaging, or the two copper tabs separate. Turned it off and then tried it again and it hummed for a few and the something glowed red and then stopped humming. Inspect for any damage to wires or wire casing. It was working fine (all 3 speeds) until yesterday. Hi Joe, Low Flow would be indicating that the water flow coming into the pump, heater or salt system is insufficient. If you have an electric motor repair shop in town, they may have it in stock, or order it online. For Use With: Hayward AquaTrol Pool Chlorine Generator Brand: HAYWARD REVIEWS Q&A Powered by TurnTo Review More Purchases | My Posts There are no reviews for this item. If the motor shaft wont turn, you can work it loose by spinning the shaft with pliers on the front end of the shaft, or a 7/16 wrench on the back end of the shaft. If thats not the air leak, check the pump lid o-ring, Superpump square lid rings sometimes get twisted easily. Internal electrical faults in the pump, such as a short circuit or improper ground, also can cause the device to draw more power than necessary and excess heating. Hi Craig, could be a clogged filter, needing a flush out and perhaps a filter soak in DE Filter Cleaner. We have a Hayward ultra pro lx series pump for our above ground pool. Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. I have backwashed the filter and the water is clear. last year, I replaced the Sand & O ring on the filter, and I resealed the O ring on both the filter & Pump with O ring lube. I then tried the pump at various speeds and it did not prime and circulate the water through the pool. Today two years later, same company opened pool,pump stuck and want to install another 3400vsp for $1330. Wait for the number to. Chapter 1: The Evil Emperor's Son. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. It wont respond to the controls at all. Please contact me at mbrad39972@hotmail.com. Perflex filters can also leak out of the bump handle, this fix usually involves replacing the shaft o-rings. Please advise ). Thoughts? Only get big time cavitation and the basket empties about half. Im being advised by an electrician that my Hayward pump has a dead short in it. Water at the base of the pump: 1. could be from a loose pump lid, dripping when the pump is off, 2. could be a leaking outlet pipe fitting, oozing from where water leaves the pump, and running down the sides of the volute, and dripping off the bottom, or 3. could be the shaft seal failing, behind the impeller. They function as the starting battery for the motor, to help it get up to speed quickly. I dropped $200 on a new pump and it is doing the same thing. 240v Input voltage is present. It is usually set to run at high rpm early morning and that is before sun hits it. Pumps can also leak water from the shaft seal, which can appear to be a housing/seal plate leak, but will leak only directly from the bottom. Loose pump lid, filter lid, air bleeder, probably around the filter, allowing the filter to drain down, and fill with air. If you have other questions, you can email me Davy, at swimmers@intheswim.com. My diffuser does not tightly fit into my seal plate. Hi Matt, sound like the bearings have gone bad, and now they are so bad that the shaft has locked up or is binding, and that trips the breaker. Hi Todd, ok I understand check the seal to make sure it is properly seated, and that the spring half is not turned backwards (should be hard plastic side toward motor, soft rubber side toward impeller, in most cases). "@context": "https://schema.org/",
I used electrical tape so the impeller Valves were replaced with pipe and silicone applied to gaskets and O-rings during install and again yesterday while I was checking this list. A leaking shaft seal or drain plug could also drain the pump after some time. Towards the end of last year the pump itself would work but the salt water fixture would not (like it would light up initially but then go to black), I wasnt sure if it was a short or something in either part but ignored it since the season was almost over. This just started. But, If you get no noise at all when you turn on the pump, no humming or grinding, or breaker tripping then check all the power connections, and check for power entering the motor, using a multimeter to test the terminals where the 2 wires connect. Typically, the LED light should shut off after 60 seconds. If any of these readings are outside limits, replace motor. The issue is not a pump problem, not a filter problem, but a multiport valve problem. Also make sure that the pump has no air leaks from loose pipes, loose pump lid, low water level in pool For you Scott, the next step is to shut off power to pump and remove the Blue, Black and Red wires (page 4 owners manual) from the drive and check each motor lead to ground. Hose it off well, and inspect the tubes for any holes, and if found, replace them with new. Any tips on getting the cover off to get to the capacitor (after removing the two screws)? I replaced the rod, and now my lid will not go down, the rod is the exact same as the other. Typically, any dilemmas with your Hayward pool pump are likely related to either electrical or plumbing situations. I have removed and tested the capacitor it appears OK I then removed the thermostat to try to access the shaft and turn it with a 7/17 wrench, but the protrusions on the casting and other spring mounted stuff appear to make it impossible to get a grip on the shaft. Motor running very hot, almost like in a bind. The most likely is an air leak, and the usual places are 1) pump lid not tight enough or not lubed, or bad o-ring, or loose drain plugs (or without thread sealant or o-ring). Last year it worked great. The waste tube on my filter is filler while my pump is running. Increased flow this year may be from the new sand, and higher flow makes it easier for air leaks to appear. By morning all the dead algae filters back into the pool and it take about 4 days to clear. Have a Hayward variable that was replaced last year. NO one can get the cover off the darn thing. Silicone lube can also be used, but dont use petroleum based lubes that can eat the rubber. switch in the center. Is the motor set to accept 220V, and matching what you measure at the motor terminals? After connecting the device, the flow led flashes for one minute and turns off. Hi Paul, could it be vibration noise? I checked the wiring, replaced the breaker, cleaned the pump impeller, motor vents are clean. If i knew what make/model of pump you have, I could be more specific. my two speed Hayword pump clicks when Everything coming in appears to be tight. Checked everything still doesnt work . JavaScript is disabled. in the filter. Could also be loose connections on the wires, or insect infestation on the contacts. When pumps dont run for a long time, they are susceptible to rust forming in between the stator and rotor. BUT THE BEARINGS. See if your test button has popped out on the outlet, or perhaps you have one on the breaker, a test/reset button. Flip timeclock switch on, inspect time clock motor gears (Intermatic clocks) for good timer motor, and inspect wiring from timer to pump. I would start by lubing the pump lid o-ring with pool lube, and trying to tighten the lid a bit more if you can. I am getting air bubbles coming from my return jets in my pool. You can also check that the phone cord wire is plugged into the interface, on underside. Could also be low water level in the pool, or a stuck skimmer weir, blocking water flow. Any thoughts? If the motor was submerged, it may not recover. Click here to shop our store. Ok I switched out the capacitor and it started up and ran for about 5 second and then blew the capacitor. I tried starting again one morning but the pump wont start. I have chalked all the connections and lubricated the basket seal. It is being practiced by thousands of pool owners just like you. the termistor was blown. Now the backwash is leaking a small amount water and the pump seems to be surging instead of running smoothly. Not sure what would cause that?!? I had my Hayward pool/spa installed about 4 years ago. The leak at the bottom of the pump, determine if its coming from the top of the pump and dripping down the sides, or if the leak is coming from directly under the pump, in the first case its usually the exit pipe threads are loose, and in the second case, its a leaking shaft seal or leaking drain plug, or sometimes a leaking volute o-ring, or the large o-ring between the seal plate and the pump housing. What more can I do or will the bubbles resolve on its own? Then there is often a switch or a timeclock that is wired in between the sub-panel and the pump. Pull the motor out of the pump and turn it on briefly, to see if the noise remains. dr myers ultrasound. "@type": "ImageObject",
Relays are usually small cubes, about 1 square, sometimes black, sometimes clear, mounted on a circuit board. '' ''' - -- --- ---- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- Click Here to View Replacement Aquarite Parts The rooms are equipped with a [] | Egypt Travel & Tourism Agency. "@type": "Person",
Yes, kind of does defeat the purpose, but you may not need to heat the pool all the time, so can still run on low-speed for many hours per day. When you installed the new lateral assy, did the standpipe come all the way up to the top of the tank, and insert neatly into the bottom of the multiport valve? Here is the manual: Now, it could also be rust inside the motor, natural when a pump sits for long periods of time, in a non-climate controlled location. Replace the seal in the same orientation as you removed it, and reassemble. put in a new motor and had the old motor repaired. Can u shed any light on what might be the culprit? Just bought a brand-new Hayward pump , starts up in primes great but in about five minutes there was no suction or water flow back to the pool . I was just wondering if you thought that could be the issue unless it could be something else. I immediately unplugged it and the plug was black and the extension Outlet was melted. Hi Patrick, so you have power from the breaker to the timer and to the switch. What should I do? They dont usually begin to flow like a gusher, but a steady trickle. Is that correct or does one go on the nut? Make sure the stationary switch, triangular shaped, screwed in at 6 oclock, is tight and intact. If your cell looks like 4A, continue to Step 4. My pump, when in the normal running position, leaks water in a slow steady flow out the tubing used for backwashing. service center location, advanced If I leave it plugged in then it stays hot, but if I unplug it then it cools off and itll work till it overheats again. If no power there, check the timer, if no power there, check the breaker, if no power there Is the main breaker in the house on? Ill look up the Drain King, is that something like a check valve? Checked pump, and appeared that pump had to keep priming . Can I replace this pump housing or do I need a new pump? Checked the connection, which seems fine. See page 40/41 in this Hayward Troubleshooting guide. Flush out the housing to clear debris, then refill with water. Hi Freddy, usually a clicking noise may be a relay, which are used in control systems for pools. Since that time the mechanical seal has failed four times each time within 2 months of operation. Yes, that sounds like a filter problem, clogged up with algae or oily substance. I check electrical from the panel breaker, to the timer to the circuit breakser to the switch to the outlet, through the wire to the pump and power is getting to the pump. Now I am looking to replace the old filter. Also installed a brand new circuit box to allow for the bigger pump its a 20A GFCI breaker with 12 gauge wire going to the pump. You can pull out the plunger and inspect, and see how it fits the valve body, at the top, should contact all sides, and be lubed well, twice per year. Check the motor diagram for the voltage wiring diagram. Check the usual spots for air coming into the pump, 1) the threaded pipe coming into the pump (did you use thread sealant? The original pump (assy A) smells burnt. Pump is 29 years old so wouldnt surprise me if impeller is failing. After about 15minutes the pump stopped and the motor was super hot. We have an Hayward SP1580X15 Power-Flo LX 1.5hp pump. Usually get 3-4x that long. Something got fried, sorry! We have just replaced the seal assembly as suggested by a Hayward rep already. Usually its 4 bolts or its a clamp band that connects the seal plate to the volute or strainer housing. new pump started up fine after primed strated to click on and off. Read up on it and seems it happens a lot and the motor drive needs to be replaced. On initial trial for ignition. },
the loosed its prime again. Do you have the correct cell size chosen in your diagnostics menu? hi quick question, i have replaced the bearing for the pump but when i reassembled the pump ive noticed that if i shut the pump off and want to turn it right back on most of the time it hums like the start capactor is not working but if i shake the pump it will start up. I checked the 20A fuse and it is good.

Is Retroviral Hypodysplasia A Real Disease, Articles H